The Association for Contract Textiles (ACT) is a non-profit trade association that sets up industrial standards related to contract fabrics. Their guidelines specify the tests that are necessary for a textile to be certified depending on its construction and intended use. The flammability test examines how a fabric will perform when it is exposed to flames or other sources of ignition. The ACT icon for flammability is given to woven, coated, and knit products. The detailed testing standards are found below.
Construction | Application | Test Method and Standard |
---|---|---|
Woven | Upholstery | Passes California Technical Bulletin 117-2013 Section 1 |
Direct Glue Wallcoverings and Adhered Panels | ASTM E84 Adhered Mounting Method Class A or Class 1 | |
Wrapped Wall Panels and Upholstered Walls | ASTM E84 Unadhered Mounting Method Class A or Class 1 | |
Panel System Furniture | Any one or a combination: UL 1286 Listed; ASTM E84 Adhered and Unadhered Mounting Method Class A or Class 1 | |
Drapery | Passes NFPA 701 Method 1 or 2 | |
Coated Fabrics | Upholstery | Passes California Technical Bulletin 117-2013 Section 1 |
Direct Glue Wallcoverings and Adhered Panels | ASTM E84 Adhered Mounting Method Class A or Class 1 | |
Wrapped Wall Panels and Upholstered Walls | ASTM E84 Unadhered Mounting Method Class A or Class 1 | |
Knit Fabrics | Upholstery | Passes California Technical Bulletin 117-2013 Section 1 |
Direct Glue Wallcoverings and Adhered Panels | ASTM E84 Adhered Mounting Method Class A or Class 1 | |
Wrapped Wall Panels and Upholstered Walls | ASTM E84 Unadhered Mounting Method Class A or Class 1 | |
Panel System Furniture | Any one or a combination: UL 1286 Listed; ASTM E84 Adhered and Unadhered Mounting Method Class A or Class 1 | |
Drapery | Passes NFPA 701 Method 1 or 2 as appropriate |